Your browser doesn't support javascript.
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtre
Ajouter des filtres

Type de document
Gamme d'année
3.
chemrxiv; 2021.
Preprint Dans Anglais | PREPRINT-CHEMRXIV | ID: ppzbmed-10.26434.chemrxiv.14555796.v1

Résumé

A commercially available and EPA/PMRA registered quaternary ammonium antimicrobial formulation was applied to stainless steel carrier disks and sent to two virology research institutes to independently determine whether samples treated with SiQAC-C18 antimicrobial material could deactivate deposited SARS-CoV-2 virions on contaminated surfaces. The results independently support a sustained antiviral effect imparted from these treated surfaces by both SARS-CoV-2 virion destruction and degradation of viral RNA. These preliminary results indicate the SiQAC-18 treated surfaces could play an important role in mitigating the communicability and fomite transmission of SARS-CoV-2.

4.
ssrn; 2021.
Preprint Dans Anglais | PREPRINT-SSRN | ID: ppzbmed-10.2139.ssrn.3769210

Résumé

Background: We assessed the safety and immunogenicity of an MF59-adjuvanted subunit vaccine for COVID-19 based on recombinant SARS-CoV-2 spike glycoprotein stabilised in a prefusion conformation by a novel molecular clamp (Sclamp).Methods: Phase 1, double-blind, placebo-controlled trial conducted in Australia (July 2020–ongoing; ClinicalTrials.gov NCT04495933). Healthy adults (18-55 years) received two doses of placebo, 5-μg, 15-μg, or 45-μg SARS-CoV-2 Sclamp, or one 45-μg dose of SARS-CoV-2 Sclamp followed by placebo, 28 days apart (n=120; 24 per group). Safety, humoral immunogenicity (ELISA, microneutralisation, pseudovirus neutralisation), and cellular immunogenicity (antigen-specific CD4+/CD8+ T-cells, antibody-secreting cells) were assessed up to 56 days after the first dose.Findings: The SARS-CoV-2 Sclamp vaccine was very well tolerated with few systemic reactions. All two-dose regimens elicited robust, broadly neutralising humoral responses. Geometric mean titres were higher than in sera from convalescent COVID-19 patients and strongly neutralised spike variants of concern, including N501Y. Moreover, humoral and cellular responses were highly correlated. However, antibodies elicited to a peptide sequence used in the molecular clamp derived from human immunodeficiency virus-1 (HIV-1) gp41 cross-reacted weakly with some HIV diagnostic screening tests.Interpretation: These first-in-human results demonstrate that a subunit vaccine comprising mammalian cell culture-derived, molecular clamp-stabilised recombinant spike protein formulated in a squalene-in-oil adjuvant elicits strong immune responses with an excellent safety profile. However, the gp41 peptide induced diagnostic interference, creates a likely barrier to widespread use and highlights the criticality of potential off-target immunogenicity during vaccine development. Studies are ongoing with alternative molecular clamp trimerisation domains to ameliorate this response.Clinical Trial Registration: ClinicalTrials.gov (NCT04495933).Funding: Coalition for Epidemic Preparedness Innovations; National Health and Medical Research Council, Queensland Government, and philanthropic sources.Declaration of Interests: KJC and DW report grants from the Coalition for Epidemic Preparedness Innovations, the National Health and Medical Research Council of Australia, and the Queensland Government, during the conduct of the study; other from ViceBio Limited, outside the submitted work; and has patents pending (AU 2018241252; BR112019019813.0; CA 3057171; CH 201880022016.9; EP 18775234.0; IN 201917038666; ID P00201909145; IL 269534; JP 2019-553883; MX/a/2019/011599; NZ 757178; KR 0-2019-7031415; SG 11201908280S; US 16/498865). JB reports personal fees from CSL Limited, during the conduct of the study, and other from CSL Limited, outside the submitted work. WZ reports grants from the National Health and Medical Research Council of Australia, the Research Grants Council of the Hong Kong Special Administrative Region, China, and the Jack Ma Foundation, during the conduct of the study. SM-H reports grants from Canarian Foundation Doctor Manuel Morales, during the conduct of the study. KJS reports grants from the the Australian Medical Research Future Fund, during the conduct of the study. AWC reports grants from the Australian Medical Research Future Fund and a National Health and Medical Research Council of Australia Career Development Fellowship, during the conduct of the study. BDW reports grants from the National Health and Medical Research Council of Australia, the Australian Medical Research Future Fund, and the Victorian State Government, during the conduct of the study. PMH reports grants from the Australian Medical Research Future Fund, during the conduct of the study. DP reports grants from the National Health and Medical Research Council of Australia, the A2 Milk Foundation, and the Jack Ma Foundation, during the conduct of the study. CR reports grants from the Coalition for Epidemic Preparedness Innovations, during the conduct of the study. PRY reports grants from the Coalition for Epidemic Preparedness Innovations, the National Health and Medical Research Council of Australia, and the Queensland Government, during the conduct of the study; grants from ViceBio Limited, outside the submitted work; and a patent issued (US 2020/0040042). FLM, Zl, DKW, PE, JAL, STMC, NM, SA, CLH, KH, PG, LH, THON, MHT, PT, JB, PCR, SN, SC, TH, KK, KS, and TPM have nothing to disclose.Ethics Approval Statement: The protocol was approved by the Alfred Health Human Research Ethics Committee (2020001376/334/20).


Sujets)
Infections à VIH , COVID-19 , Pelade
5.
researchsquare; 2020.
Preprint Dans Anglais | PREPRINT-RESEARCHSQUARE | ID: ppzbmed-10.21203.rs.3.rs-127019.v1

Résumé

Introduction: The sudden arrival of the COVID-19 pandemic placed significant stresses on supply chains including viral transport medium (VTM). The VTM that was urgently required needed to support viral replication, as well as other routine diagnostic approaches. We describe the preparation and validation testing of VTM for rapidly expanding diagnostic testing, where the capacity of the VTM to preserve viral integrity, for culture, isolation and full sequence analysis, was maintained.MethodsVTM was prepared using different methods of sterilization then ‘spiked’ with virus. The VTM was investigated using viral culture in Vero cells, and for nucleic acid detection by quantitative PCR (qPCR).ResultsThe best results were obtained by filter and autoclave-based sterilization. The VTM proved robust for culture-based analyses provided the inoculated VTM was stored at 4 o C, and tested within 48 hours. The filtered VTM also supported PCR-based diagnosis for at least 5 days when the mock inoculated VTM was held at room temperature (RT).DiscussionThe manual handling of VTM production, including filling and sterilization, was optimized. SARS-CoV-2 was spiked into VTM to assess different sterilization methods and measure the effects of storage time and temperature upon VTM performance. While most diagnostic protocols will not require replication competent virus, the use of high quality VTM will allow for the next phase of laboratory analysis in the COVID-19 pandemic, including drug and antibody susceptibility analysis of re-isolated SARS--CoV-2, and for the testing of vaccine escape mutants.


Sujets)
COVID-19
6.
medrxiv; 2020.
Preprint Dans Anglais | medRxiv | ID: ppzbmed-10.1101.2020.05.31.20118273

Résumé

Background: Robust serological assays are essential for long-term control of the COVID-19 pandemic. Many recently released point-of-care (PoCT) serological assays have been distributed with little pre-market validation. Methods: Performance characteristics for five PoCT lateral flow devices approved for use in Australia were compared to a commercial enzyme immunoassay (ELISA) and a recently described novel surrogate virus neutralisation test (sVNT). Results: Sensitivities for PoCT ranged from 51.8% (95% CI 43.1 to 60.4%) to 67.9% (95% CI 59.4-75.6%), and specificities from 95.6% (95% CI 89.2-98.8%) to 100.0% (95% CI 96.1-100.0%). Overall ELISA sensitivity for either IgA or IgG detection was 67.9% (95% CI 59.4-75.6), increasing to 93.8% (95% CI 85.0-98.3%) for samples >14 days post symptom onset. Overall, sVNT sensitivity was 60.9% (95% CI 53.2-68.4%), rising to 91.2%% (95% CI 81.8-96.7%) for samples collected >14 days post-symptom onset, with a specificity 94.4% (95% CI 89.2-97.5%), Conclusion: Performance characteristics for COVID-19 serological assays were generally lower than those reported by manufacturers. Timing of specimen collection relative to onset of illness or infection is crucial in the reporting of performance characteristics for COVID-19 serological assays. The optimal algorithm for implementing serological testing for COVID-19 remains to be determined, particularly in low-prevalence settings.


Sujets)
COVID-19 , Infections
7.
biorxiv; 2020.
Preprint Dans Anglais | bioRxiv | ID: ppzbmed-10.1101.2020.03.05.976167

Résumé

Fundamental aspects of SARS-CoV-2 biology remain to be described, having the potential to provide insight to the response effort for this high-priority pathogen. Here we describe the first native RNA sequence of SARS-CoV-2, detailing the coronaviral transcriptome and epitranscriptome, and share these data publicly. A data-driven inference of viral genetic features and evolutionary rate is also made. The rapid sharing of sequence information throughout the SARS-CoV-2 pandemic represents an inflection point for public health and genomic epidemiology, providing early insights into the biology and evolution of this emerging pathogen.

SÉLECTION CITATIONS
Détails de la recherche